Snowflake 002009 (22000): Invalid binary data

Binary data does not conform to the expected format or length.

Understanding Snowflake and Its Purpose

Snowflake is a cloud-based data warehousing service that provides a platform for data storage, processing, and analysis. It is designed to handle large volumes of data with ease, offering scalability, flexibility, and performance. Snowflake allows organizations to consolidate data from various sources, enabling advanced analytics and business intelligence.

Identifying the Symptom: Invalid Binary Data

When working with Snowflake, you may encounter the error code 002009 (22000): Invalid binary data. This error typically arises when the binary data being processed does not match the expected format or length, causing the operation to fail.

Common Scenarios

  • Loading binary data into a table with incorrect formatting.
  • Data transformation processes that alter the binary data structure.
  • Incorrect data type definitions in table schemas.

Explaining the Issue: Error Code 002009

The error code 002009 (22000) indicates that the binary data provided does not conform to the expected format or length. This can occur due to several reasons, such as incorrect data type specifications, data corruption during transfer, or mismatches in data encoding.

Technical Details

Binary data in Snowflake is typically represented using the BINARY or VARBINARY data types. These types require data to be in a specific format, and any deviation from this format can trigger the error.

Steps to Resolve the Invalid Binary Data Error

To resolve the 002009 (22000): Invalid binary data error, follow these steps:

Step 1: Verify Data Format

Ensure that the binary data is correctly formatted. Check the source of the data and confirm that it adheres to the expected binary format. If necessary, use data conversion tools to reformat the data.

Step 2: Check Data Length

Verify that the length of the binary data matches the expected length defined in the table schema. If the data is too long or too short, adjust it accordingly.

Step 3: Validate Data Type Definitions

Review the table schema to ensure that the data types for binary columns are correctly defined. Use the DESCRIBE TABLE command to inspect the schema:

DESCRIBE TABLE your_table_name;

Make any necessary adjustments to the data types to accommodate the binary data.

Step 4: Use Snowflake's Data Loading Tools

Utilize Snowflake's data loading tools, such as COPY INTO, to ensure data is loaded correctly. These tools provide options for handling binary data and can help prevent format-related issues.

Additional Resources

For more information on handling binary data in Snowflake, refer to the following resources:

By following these steps and utilizing the resources provided, you can effectively resolve the 002009 (22000): Invalid binary data error and ensure smooth data processing in Snowflake.

Never debug

Snowflake

manually again

Let Dr. Droid create custom investigation plans for your infrastructure.

Book Demo
Automate Debugging for
Snowflake
See how Dr. Droid creates investigation plans for your infrastructure.

MORE ISSUES

Made with ❤️ in Bangalore & San Francisco 🏢

Doctor Droid