Supabase Database Numeric value out of range error when a numeric value exceeds the allowed range.

The numeric value being inserted or updated is outside the permissible range for the specified column type.

Understanding Supabase Database

Supabase is an open-source alternative to Firebase, providing developers with a suite of tools to build applications faster. It includes a real-time database, authentication, and storage services. Supabase Database, specifically, is a PostgreSQL database that offers robust features and scalability for modern applications.

Identifying the Symptom

When working with Supabase Database, you might encounter an error message that reads: 22003: Numeric value out of range. This error typically occurs when a numeric value exceeds the allowed range for the column type in your database schema.

Exploring the Issue

What Does Error Code 22003 Mean?

Error code 22003 is a standard PostgreSQL error indicating that a numeric value is outside the permissible range for its data type. This can happen when inserting or updating data in a table where the value exceeds the maximum or minimum limits defined by the column's data type.

Common Scenarios

This error often arises in scenarios where the data type is not appropriately chosen for the expected range of values. For example, using an INTEGER type for a column that might store values larger than 2,147,483,647 (the maximum for a 32-bit integer) can lead to this error.

Steps to Fix the Issue

1. Review Your Schema

First, examine the schema of the table where the error occurred. Identify the column that is causing the issue and check its data type. You can use the following SQL query to inspect the table structure:

SELECT column_name, data_type
FROM information_schema.columns
WHERE table_name = 'your_table_name';

2. Adjust the Data Type

If the column's data type is not suitable for the range of values you need to store, consider altering the column to a more appropriate type. For instance, if you need to store larger numbers, you might switch from INTEGER to BIGINT:

ALTER TABLE your_table_name
ALTER COLUMN your_column_name TYPE BIGINT;

3. Validate Data Before Insertion

Implement checks in your application code to ensure that the data being inserted or updated is within the acceptable range. This can prevent the error from occurring in the first place.

Additional Resources

For more information on PostgreSQL data types and their ranges, you can refer to the official PostgreSQL Numeric Types Documentation. Additionally, Supabase provides comprehensive documentation to help you understand and utilize its features effectively.

By following these steps, you can resolve the 22003: Numeric value out of range error and ensure your Supabase Database operates smoothly.

Master

Supabase Database

in Minutes — Grab the Ultimate Cheatsheet

(Perfect for DevOps & SREs)

Most-used commands
Real-world configs/examples
Handy troubleshooting shortcuts
Your email is safe with us. No spam, ever.

Thankyou for your submission

We have sent the cheatsheet on your email!
Oops! Something went wrong while submitting the form.

Supabase Database

Cheatsheet

(Perfect for DevOps & SREs)

Most-used commands
Your email is safe with us. No spam, ever.

Thankyou for your submission

We have sent the cheatsheet on your email!
Oops! Something went wrong while submitting the form.

MORE ISSUES

Made with ❤️ in Bangalore & San Francisco 🏢

Doctor Droid